Cornelius CH1500-CH7500 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para não Cornelius CH1500-CH7500. Cornelius CH1500-CH7500 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
CHILLER
Models: CH1500–CH7500
Operators Manual
with Installation,
Service, and Parts
PRINTED IN U.S.A
IMI CORNELIUS INC; 2006©
IMI CORNELIUS INC
Telephone (800) 551–4423 Fax (800) 394–5140
Part No. 91961OPR
September 12, 2006
Revised: N/A
Revision: A
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION
This Manual must be read and understood before installing or operating this equipment
Vista de página 0
1 2 3 4 5 6 ... 25 26

Resumo do Conteúdo

Página 1 - CHILLER

CHILLER Models: CH1500–CH7500Operator’s Manualwith Installation, Service, and PartsPRINTED IN U.S.AIMI CORNELIUS INC; 2006©IMI CORNELIUS INCTelephone

Página 2 - TABLE OF CONTENTS

791961OPRSTART UPWATER FLOW START-UPChiller with PumpIt is important to check the pump rotation on the three phase units. Remove the lower side panel

Página 3 - TABLE OF CONTENTS (cont’d)

891961OPRDual Point Adjustment1. To set the “SET POINT” for Level 1. Press and release the “SET” button, Re1 should be displayed.2. Press the “SET” bu

Página 4 - GENERAL INFORMATION

991961OPR3. CONTROL POWER LIGHT- A white light that indicates that Chiller control power is present.4. COOLING LIGHT- A green light that indicates ref

Página 5 - INSTALLATION

1091961OPRMAINTENANCECAUTION: Disconnect electrical power before performing any of the following maintenanceprocedures. The Chiller will require very

Página 6 - PLUMBING

1191961OPRFLUID RECOMMENDATIONChillers are designed to operate with water to provide maximum performance for tempera-tures of 40F–100F.Distilled Wat

Página 7 - Chiller without Reservoir

1291961OPRWARNING: If repairs are to be made to the refrigeration system, make sure electrical poweris disconnected from the unit.TROUBLESHOOTINGIMP

Página 8

1391961OPRTrouble RemedyProbable CauseD. Refrigerant loss. D. Check the sight glass. If bubblesare seen flowing through it, theChiller needs to be lea

Página 9

1491961OPRSERVICEWhen servicing a Chiller, it is important to note the information contained on the data plate located in the upperrear of the unit.If

Página 10 - START UP

1591961OPRTHIS PAGE LEFT BLANK INTENTIONALLY

Página 11 - Control Panel

1691961OPRSAFETY CONTROLSEach Chiller is provided with three standard safety controls. These controls are arranged in series in the controlcircuit to

Página 12 - 91961OPR

i91961OPRTABLE OF CONTENTSPageGENERAL INFORMATION 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 13 - MAINTENANCE

1791961OPRTXV EQUALIZERLINETXV SENSINGBULBTXVEVAPORATORLIQUID LINESOL. VALVEHOT GASBYPASSVALVECOMPRESSORLOW PRESSURESWITCHHIGH PRESSURESWITCHSIGHT GLA

Página 14 - FLUID RECOMMENDATION

1891961OPRPARTS LIST134567891011121314151617181920212223242526410FIGURE 8. CHILLER PARTS BREAKDOWNIndexNo.Description1 1/2” FPT Coupling2 Thermowell,

Página 15 - TROUBLESHOOTING

19 91961OPR12345FIGURE 9. PUMP AND TANK COMPONENTSIndexNo.Description1 Thermowell, Temperature Control2 Temperature Probe3 Tank AssemblyIndexNo.Descri

Página 16

2091961OPR1234567FIGURE 10. ELECTRICAL BOX COMPONENTSIndexNo.Description1 Low Temperature Thermostat2 Control Transformer3 Contactor, Compressor4 High

Página 17

2191961OPRWARRANTYIMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship un-der normal use and ser

Página 19 - SAFETY CONTROLS

IMI CORNELIUS INC.www.cornelius.com

Página 20

ii91961OPRTABLE OF CONTENTS (cont’d)PageLIST OF FIGURESFIGURE 1. INSTALLATION DETAILS 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 21 - PARTS LIST

191961OPRGENERAL INFORMATIONINTRODUCTIONRemcor “CH” Series Refrigerated Recirculating Water Chillers are designed to provide a continuous flow ofclean

Página 22 - 19 91961OPR

291961OPRINSTALLATIONLOCATIONInstall the Chiller indoors in a well ventilated area where ambient temperatures will never fall below 40F or riseabove

Página 23 - 2091961OPR

391961OPRELECTRICALAll wiring must conform to the National Electric Code and any applicable local codes. The Chiller must be PERMANENTLY wired by mean

Página 24 - WARRANTY

491961OPRChiller with ReservoirThe reservoir can be filled by removing the water fill cap located on the upper rear of the Chiller (See Fluid Rec-omme

Página 25

591961OPRRESERVOIRLOW TEMP. CONTROLFROM PROCESSCHILLER INLETEVAPORATORPUMP BYPASS VALVECHILLER OUTLETTO PROCESSFIGURE 2. CHILLER PLUMBING SCHEMATIC WI

Página 26 - IMI CORNELIUS INC

691961OPRTHIS PAGE LEFT BLANK INTENTIONALLY

Comentários a estes Manuais

Sem comentários