Reach-In Refrigerator Installation Manual
© 2004, IMI Cornelius Inc. - 1 - Publication Number: 630460252INS
INSTALLATION MANUAL
Reach-In Refrigerators
COR20RRTM, COR22RRTM, COR40RRTMD,
COR48RRTMD, COR74RRTMT
CAUTION - Only trained and certified electrical, plumbing and refrigeration technicians should
service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL
CODES.
CHECK FOR SHIPPING DAMAGE
Prior to leaving the factory, each cabinet is thoroughly inspected and performance tested up to 12 hours
to assure proper operating temperatures.
Check the crate thoroughly for signs of shipping damage.
If signs of shipping damage are present:
If the damage is severe and obvious, refuse the shipment. The carrier will return the cabinet to the
factory. Call the factory immediately, noting that the shipment was refused and we’ll ship a replacement
cabinet and handle the freight claim.
If no obvious crate damage is present, within two hours of receiving the cabinet from the carrier, remove
the front and side panels to inspect for concealed damage.
1. If concealed damage is found, call the carrier immediately, save all crating materials, and file the
necessary freight claim with the carrier.
2. If no concealed damage is present, reassemble the crate to protect the cabinet for final location
delivery.
WHERE TO LOCATE THE CABINET
• Place the cabinet on a surface strong enough to support the combined weight of the cabinet and the
product load and solid enough to prevent vibration. Guideline: estimate 35 pounds per cubic foot of
storage space.
• Locate the cabinet on a level surface. Minor unevenness can be compensated for by the adjustable
legs or shimming the base or casters.
• Place the cabinet in areas where the ambient room temperatures are between 50
o
F and 90
o
F.
Excessive heat will affect performance and may cause condensation.
• Locate the cabinet in well-ventilated areas. The cabinet should be protected from heat sources and
direct sun’s rays. If the cabinet is in front of a window, provide an awning or shade to shield the cabinet
from direct sunlight.
Release Date: June 16, 2004 www.cornelius.com Revision: A
Vista de página 0
1 2 3 4 5 6 ... 11 12

Resumo do Conteúdo

Página 1 - INSTALLATION MANUAL

Reach-In Refrigerator Installation Manual© 2004, IMI Cornelius Inc. - 1 - Publication Number: 630460252INSINSTALLATION MANUALReach-In RefrigeratorsCOR

Página 2 - REMOVE THE DOOR AND HINGES

Reach-In Refrigerator Installation ManualPublication Number: 630460252INS - 10 - © 2004, IMI Cornelius Inc.COR40RRTMDFIGURE 13PERIMETER HEATERTEMP. CO

Página 3 - INSTALL LEGS AND CASTERS

Reach-In Refrigerator Installation Manual© 2004, IMI Cornelius Inc. - 11 - Publication Number: 630460252INSCOR48RRTMDFIGURE 14WHITEGREENBLACKGREENBLAC

Página 4 - Top mounted units

Reach-In Refrigerator Installation ManualPublication Number: 630460252INS - 12 - © 2004, IMI Cornelius Inc.COR74RRTMTFIGURE 15WHITEGREENBLACKGREENBLAC

Página 5 - FIGURE 7

Reach-In Refrigerator Installation ManualPublication Number: 630460252INS - 2 - © 2004, IMI Cornelius Inc.• If the condensing unit is located in th

Página 6 - Plug in your cabinet

Reach-In Refrigerator Installation Manual© 2004, IMI Cornelius Inc. - 3 - Publication Number: 630460252INSthe hinge until the door is properly aligned

Página 7 - CABINET START UP

Reach-In Refrigerator Installation ManualPublication Number: 630460252INS - 4 - © 2004, IMI Cornelius Inc.After the legs are installed, level the cabi

Página 8 - WIRING DIAGRAMS

Reach-In Refrigerator Installation Manual© 2004, IMI Cornelius Inc. - 5 - Publication Number: 630460252INSType 1 - Insert the drain trap into the drai

Página 9 - COR22RRTM

Reach-In Refrigerator Installation ManualPublication Number: 630460252INS - 6 - © 2004, IMI Cornelius Inc.RELEASE THE COMPRESSOR TIE-DOWN BOLTSCheck t

Página 10 - COR40RRTMD

Reach-In Refrigerator Installation Manual© 2004, IMI Cornelius Inc. - 7 - Publication Number: 630460252INSAlways check the amperage rating of the cond

Página 11 - COR48RRTMD

Reach-In Refrigerator Installation ManualPublication Number: 630460252INS - 8 - © 2004, IMI Cornelius Inc.WIRING DIAGRAMSCOR20RRTMFIGURE 11PERIMETER H

Página 12 - COR74RRTMT

Reach-In Refrigerator Installation Manual© 2004, IMI Cornelius Inc. - 9 - Publication Number: 630460252INSCOR22RRTMFIGURE 12WHITEGREENBLACKGREENBLACKW

Comentários a estes Manuais

Sem comentários