Ice Frost Operators Manual
© 2004, IMI Cornelius Inc. - 7 - Publication Number: M620919596OPR
ICE FROST GENERIC (POST-MIX)
Switch the machines main switch to the ON position (1).
Make sure the switch (L1) is in the OFF position (0) - Figure
6 - (switch L1 controls the flow of the products in the bowls).
Turn mixing motors OFF immediately. Do not run units with
bowls empty.
Using an 8 mm socket wrench (E1), loosen the nut that
holds the post-mix valve (D1).
Twist nozzle counter-clockwise (F1), lift the post-mix valve
(D1) up slightly and turn it towards the outside. leaving
nozzle and coupling attached to the bowl.
FIGURE 6
Brix and Ratio Procedure
Now pull the post-mix valve out further and tighten the 8mm
nut using the socket wrench (E1) - Figure 7.
FIGURE 7
Remove the post-mix valves nozzle and apply the relevant
dose calibrator/separator (G1), then the relative measuring
cup (H1) and push the micro switch on the valve (l1) until
both the soda water and the syrup run into the measuring
cup separately (Figure 8).
Check the BRIX: turn the water adjustment screw on the
solenoid valve clockwise to increase or counter-clockwise to
decrease the amount of water in the product.
When the desired mix has been found, remove the parts G1
and H1, replace the spout on the post-mix solenoid valve,
then position it in its original seating, performing the previous
operations in reverse order.
A refractometer may be used as an alternative to ratio
measurement.
FIGURE 8
Repeat the same operations for the second bowl.
Once the adjustments have been carried out for each bowl, place the switch (L1) in the ON position
(1).
Both bowls will begin to fill up when the level sensor is activated.
Turn mixing motors ON (located on the control board).
Unit has built in delays for compressor and bowl fill switch.
During initial filling it is normal for some foaming to take place. Bowl level management will adjust as it
freezes down and foam will dissipate.
Vista de página 10