IDC 255 Progate Drive Thru Service Manual
© 2006, IMI Cornelius Inc. - 17 - Publication Number: 621057419SER
4. Using a plastic pail, prepare approximately five (5) gallons of sanitizing solution.
5. Rinse the B–I–B disconnects in the sanitizing solution.
6. Sanitizing fittings must be attached to each B–I–B disconnect. If these fittings are not available, the
fittings from empty B–I–B bags can be cut from the bags and used. These fittings open the
disconnect so the sanitizing solution can be drawn through the disconnect.
7. Place all the B–I–B disconnects into the pail of sanitizing solution. Operate all the valves until the
sanitizing solution is flowing from the valve. Allow sanitizer to remain in lines for fifteen (15) minutes.
8. Remove the nozzle and syrup diffuser from each valve and clean them in a soap solution. Rinse
with clean water and reassemble the nozzle and syrup diffuser to the valve.
9. Remove the sanitizing fittings from the B–I–B disconnects and connect the disconnects to the
appropriate
B–I–B container. Operate the valves until all sanitizer has been flushed from the system and syrup
is flowing freely.
YEARLY
Water Pump Maintenance (or after water system disruption)
The water pump water strainer screen and the liquid dual check valve must be inspected and cleaned at
least once a year under normal circumstances and after any water system disruption (plumbing work,
earthquake, etc.). Call a qualified Service Person to inspect and clean the strainer screen and the liquid
dual check valve.
Cleaning CO
2
Gas Check Valve
The CO
2
gas check valve, located on the carbonated water tank, must be inspected and serviced at least
once a year under normal conditions and after any CO
2
system servicing disruption. Call a qualified
Service Person to inspect and clean the CO
2
gas check valve.