IMPORTANT:
TO THE INSTALLER.
It is the responsibility of
the Installer to ensure that
the water supply to the
dispensing equipment is
provided with protection
against backflow by an air
gap as defined in
ANSI/ASME A112.1.2-1979;
or an approved vacuum
breaker or other such
method as proved effective
by test.
Water pipe connections
and fixtures directly
connected to a potable
water supply shall be
sized, installed, and
maintained according to
Federal, State, and Local
Codes.
Operators Manual
THE PROFILEtICE/DRINK DISPENSER
Model: PR150 BC
PRINTED IN U.S.A
IMI CORNELIUS INC; 2001–2007©
IMI CORNELIUS INC
www.cornelius.com
Telephone (800) 238–3600
Part No. 620918702
October 5, 2001
Revision Date: February 27, 2007
Revision: D
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION
This Manual must be read and understood before installing or operating this equipment
Vista de página 0
1 2 3 4 5 6 ... 31 32

Resumo do Conteúdo

Página 1 - Model: PR150 BC

IMPORTANT:TO THE INSTALLER.It is the responsibility ofthe Installer to ensure thatthe water supply to thedispensing equipment isprovided with protecti

Página 2 - TABLE OF CONTENTS

7620918702FIGURE 2. FLOW DIAGRAM

Página 3

8620918702THIS PAGE LEFT BLANK INTENTIONALLY

Página 4 - SAFETY INFORMATION

9 620918702MAINTENANCEThe following dispenser maintenance should be performed at the intervals indicated.DAILY (or as required)Remove foreign material

Página 5 - 2620918702

106209187021. Remove cover from the dispensing valve by lifting the front cover up 1/4 inch and pulling forward.2. Install syrup diversion tube assemb

Página 6 - SAFETY PRECAUTIONS

11 6209187022. Install syrup diversion tube assembly on the dispensing valve by pushing the rubber end of the syrup diver-sion tube onto the syrup out

Página 7

12620918702696667657377FIGURE 4. AUGER ASSEMBLYCLEANING AND SANITIZING INSTRUCTIONSWARNING: Disconnect electrical power to the dispenser before cleani

Página 8

13 620918702C. Wash cup rest with soap solution and rinse with potable water. Install cup rest in drip tray.D. Clean all exterior surfaces of the disp

Página 9 - FIGURE 1. MOUNTING TEMPLATE

14620918702J. Reassemble the agitator assembly and disc into the hopper. Make certain the retaining screw is tight.K. Using a mechanical spray bottle

Página 10 - FIGURE 2. FLOW DIAGRAM

15 62091870211. For post-mix valves, remove the nozzle and syrup diffuser and clean them in a mild soap solution.Rinse with clean water and reassemble

Página 11 - 8620918702

16620918702FIGURE 7. WIRING DIAGRAM

Página 12 - MAINTENANCE

i620918702TABLE OF CONTENTSSAFETY INFORMATION 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 13

17620918702FIGURE 8. LADDER DIAGRAM

Página 14 - AUGER ASSEMBLY BREAKDOWN

18620918702THIS PAGE LEFT BLANK INTENTIONALLY

Página 15 - Cleaning Dispenser

19620918702TROUBLESHOOTINGIMPORTANT: Only qualified Personnel should service internal components or electrical wiring.WARNING: If repairs are to be ma

Página 16 - 620918702

20620918702Trouble RemedyProbable CauseAGITATOR TURNS, AUGERDOES NOT TURN (CONT’D)C. Inoperative rectifier. C. Replace rectifier.D. Ice jam. D. Clear

Página 17

21 620918702ILLUSTRATED PARTS LIST123412813961711581334959122133791188978871141421411348611511696859812124.7475101136105110112109838891171271038090168

Página 18 - ICE AUGER SPEED CONTROL

2262091870214551076391140124126651258412413812072119732527373873929104113241136511126 329595525310212336952295441007035473536309513069 20 18 19 979551

Página 19 - FIGURE 7. WIRING DIAGRAM

23 620918702675668557457715466616081627664431084950462815361353535362314412936

Página 20 - FIGURE 8. LADDER DIAGRAM

24620918702PR150BC ASSEMBLYItemNo. Part No. Name1 1919 Mounting Block Ass’y, UF-12 1950 Cover, Valve, Back3 1951 Cover, Valve, Front4 1966 Dispensing

Página 21 - 18620918702

25 620918702PR150BC ASSEMBLY (CONT’D)ItemNo. Part No. Name45 90432 Label, Warning, Disconnect46 90580 Label, Identification Data47 90629 Label, Clean

Página 22 - TROUBLESHOOTING

26620918702PR150BC ASSEMBLY (CONT’D)ItemNo. Part No. Name87 620045724620045727Base, Tower LHBase, Tower RH88 620045904 Bracket, Dispense Switch89 620

Página 23

ii620918702TABLE OF CONTENTSFIGURE 1. MOUNTING TEMPLATE 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FIGURE 2. FLOW DIAG

Página 24 - ILLUSTRATED PARTS LIST

27 620918702PR150BC ASSEMBLY (CONT’D)ItemNo. Part No. Name132 620704604 Fitting, 3/8 By 1/2 MPT133 620708524 Cup Rest134 620705201 Pushon Nut, 3/1613

Página 25

28620918702WARRANTYIMI Cornelius Inc. Products Company warrant that all equipment and parts are free from defects in material andworkmanship under nor

Página 26 - 23 620918702

www.cornelius.com(800) 238-3600IMI CORNELIUS INC.

Página 27 - PR150BC ASSEMBLY

1 620918702SAFETY INFORMATIONRecognize Safety InformationThis is the safety-alert symbol. When you see thissymbol on our machine or in this manual, be

Página 28 - PR150BC ASSEMBLY (CONT’D)

2620918702THIS PAGE LEFT BLANK INTENTIONALLY

Página 29

3620918702SAFETY PRECAUTIONSThis dispenser has been specifically designed to provide protection against personal injury and eliminate contamination of

Página 30

4620918702THIS PAGE LEFT BLANK INTENTIONALLY

Página 31 - WARRANTY

5 620918702INSTALLATION INSTRUCTIONS COUNTER HEIGHT(INCHES)DISPENSERDEPTH(INCHESAVAILABLE SPACE BELOW DISPENSER(INCHES)USE KIT NO.30 29 1 CONSULT FACT

Página 32 - IMI CORNELIUS INC

6620918702FOOT PRINT OF UNITON COUNTERTOP29 – 5/827–3/1625–3/431–7/8THE ABOVE FIGURE SHOWS THE REQUIRED CUTOUT FOR PLACING THE ICE DISPENSER INTO A CO