Cornelius SID650A/80-B Manual do Operador Página 37

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 36
33 90846
YES
NO
IS
ONE OR MORE
FAUCETS
INOPERATIVE?
4. BEVERAGE SYSTEM PROBLEM
IS
BEVERAGE
COLD?
IS
BEVERAGE PROPERLY
CARBONATED?
IS
BEVERAGE TOO
SWEET?
IS
BEVERAGE TOO
WATERY?
DONE
1. CHECK WIRING CONNECTIONS TO
INOPERATIVE FAUCETS.
2. REPLACE INOPERATIVE FAUCETS.
3. CHECK WIRING CONNECTIONS FROM 24 V.
TRANSFORMER.
4. CHECK 24 V. TRANSFORMER.
1. CHECK FOR ICE ON COLD PLATE. (--BC
MODELS)
2. CHECK REMOTE COOLING SYSTEM. (--B
MODELS)
1. CHECK CO
2
PRESSURE.
2. CHECK CARBONATOR.
1. CHECK WATER SUPPLY PRESSURE.
2. CHECK SUPPLY FILTER.
3. CHECK CARBONATOR.
4. CHECK FAUCET BRIX.
1. CHECK IF SYRUP BIB IS EMPTY.
2. CHECK CO
2
PRESSURE.
3. CHECK FAUCET BRIX.
YES
YES
YES
YES
NO
NO
NO
NO